Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : Tianan Electric
Model Number : FT16-40.5
Place of Origin : CHINA
MOQ : 10set
Price : Pending
Payment Terms : L/C, T/T, D/P, D/A
Supply Ability : 1000sets per year
Delivery Time : 35 work days
Packaging Details : wooden cases
Rated Voltage : 40.5KV
Rated Current : 630A
Fuse Rated Current : 100A
Earthing switch Making currrent : 31.5KA
Indoor High Voltage Vacuum Load Breaker Switch ,Load Switch - Fuse Combinations
General
FT16-40.5,FT16-40.5R is applied in power grid with AC 50HZ,rated voltage of 35Kv.It can be applied in breaking the load current,overload current and short-circuit current.The product is the main element of HXGT16-40.5 indoor AC metal-clad switchgear and DFT16-40.5 outdoor HV cable branch box.HXGT16 is especially designed for 35KV compact substation ,secondary small scale distribution substation.It is particularly the best choice of wind turbine generator system and power transmission gri equipment for control and protection of the transformer terminal.DTW is a transit station for power transmission cable ,used for outdoor cable line control ,contact,tap,branch or conversion.
Parameters
S/N | Item | Unit | Data | |||||
1 | Rated voltage | kV | 40.5 | |||||
2 | Rated frequency | Hz | 50 | |||||
3 | Rated current | A | 630 | |||||
4 | Fuse Rated current | A | 100 | |||||
5 | Rated short-time Withstand Current | KA | 20 | |||||
6 |
Rated short-circuit making Current |
s | 4 | |||||
7 | KA | 50 | ||||||
8 | Rated peak withstand current | KA | 50 | |||||
9 | Rated load breaking Current | A | 630 | |||||
10 | Rated Transfer (take-over)breaking current(with 100A fuses) | A | 2000 | |||||
11 | Earthing switch making current | KA | 31.5 | |||||
12 | FT16-40.5 main circuit resistance | uΩ | ≤200 | |||||
13 | FT16-40.5R Main circuit resistance (not including fuse link resistance) | uΩ | ≤400 | |||||
14 | Opening time | ms | 60-70 | |||||
15 | Fuse rated breaking current | KA | 31.5 | |||||
16 | Rated insulation level | 1min Power frequency withstand voltage |
phase to phase/ phase-to-ground | KV | 95 | |||
Fracture/isolating Fracture | 95/118 | |||||||
lightning impulse withstand voltage (peak value) |
Phase to phase/ phase-to-ground | 185 | ||||||
Fracture/isolating Fracture | 185/215 | |||||||
17 | Mechanical life | Load switch | Time | 10000 | ||||
Disconnector | 2000 | |||||||
Earthing switch | 2000 | |||||||
18 | Dimensions | HXGT16 | Width | mm | 1200,2000 | |||
Depth | 1600 | |||||||
Height | 1900,2000 | |||||||
DTW | Width | 1800 | ||||||
Depth | 2300 | |||||||
Height | 2100 | |||||||
![]() |
40.5KV High Voltage Load Break Switch Images |